Dow reverse osmosis membrane BW30-365

Dow reverse osmosis membrane BW30-365

Dow FLMTECBW30-365 brackish water desalination reverse osmosis membrane element
inquiry
  • Product Details

Performance characteristics

   DowFLMTECTMBW30-365The water production is increased not by raising the membrane flux or increasing the operating pressure, but by increasing the membrane area. Therefore, a very low fouling rate can be maintained, thereby maintaining a long-term high water production and prolonging the service life of the membrane elements. At the same time, its operating pressure is low, which improves the economic efficiency of the system operation.BW30-365The high effective area enables the new designROThe system uses fewer components, making it compact and saving installation costs.

When renovating the system, replace it withBW30-365When using components, the water production capacity of the original system can be increased without expansion. Or the original water production volume can be maintained while reducing the external dimensions of the device.

Product real photos

Product.jpg

Product specification

Specification.png

1,The water production capacity and desalination rate are based on the following test conditions:2000ppmNaCl,225psi(2.55MPa"25℃,pH=8.

2,The flow rate of specific components may vary, but it will not be lower than the given value15%.

3,Ensure that the deviation of the processing area is within+/-5%Within.

BW30-365The component can be placed with an inner diameter of203Inside a pressure vessel in millimeters.

Work limit

Limit.png

aWhenpHThe value exceeds10At that time, the highest temperature for continuous operation is35

bIn some cases, the presence of free chlorine and other oxidants can lead to the failure of water production membrane elements. It is recommended to remove the residual free chlorine through pre-treatment before the membrane elements come into contact with these oxidants.

Products

> Softened water equipment

> Reverse osmosis (RO) pure water equipment

> Water supply equipment

> Automatic dosing equipment

> Water purification equipment

> Ultra-pure water equipment

> Wholesale of water treatment accessories

Recommended news

Contact us

  • Wanda Plaza, Fengke Road, Fengtai District, BeijingBseat6Courtyard No.3Building No.7layer708
  • bjyuanlai@163.com
  • +86 010 59792055
  • +86 010 59792055

All rights reserved © 2026 Beijing Yuanlai Water Treatment Equipment Co., LTD All rights reserved