Maintenance and cleaning methods for reverse osmosis equipment,Reverse osmosis technology has been increasingly widely applied due to its unique superiority. The cleaning issue of reverse osmosis equipment may cause losses to many users with weak technical capabilities. Therefore, by doing a good job in the management of reverse osmosis equipment, serious problems can be avoided.
1,Low-pressure flushing of reverse osmosis equipment
Regularly perform high flow, low pressure and low pressure on the reverse osmosis equipmentpHThe flushing of the value is conducive to removing the dirt adhering to the membrane surface, maintaining the membrane performance, or when the reverse osmosis equipment feeds waterSDISuddenly increase over5.5At the above times, low-pressure flushing should be carried outSDITurn on the machine only after the value adjustment is qualified.
2,Reverse osmosis equipment shutdown protection
Due to fluctuations in production, reverse osmosis pure water machines are inevitably shut down frequently. Protective measures should be taken when they are out of service for a short or long time. Improper handling can lead to a decline in membrane performance that cannot be restored.
3Short-term storage is applicable when the service is out of service
15dThe following systems can adopt each1~3dThe method of low-pressure flushing is used to protect reverse osmosis equipment. Practice has found that water temperature20℃At the above times, water is stored in the reverse osmosis equipment3dIt will go bad and stink, and multiply in large numbers. Therefore, it is recommended that the water temperature be higher than20℃Every hour, every2dor1dLow-pressure flushing once, with water temperature lower than20℃At that time, you can do it every time3dPerform a low-pressure flush once. After each flush, all the inlet and outlet valves on the reverse osmosis device of the water purification equipment should be closed. Long-term shutdown protection applies to shutdown15dFor the above-mentioned systems, protective solution should be used at this time(agent)
Fill it into the reverse osmosis device of the water purification equipment for protection.
4.Chemical cleaning of reverse osmosis membranes
Under normal operating conditions, reverse osmosis membranes may also be contaminated by inorganic scale, colloids, microorganisms, metal oxides, etc. The deposition of these substances on the membrane surface can cause a decrease in the output or desalination rate of the reverse osmosis device in the water purification equipment, an increase in pressure difference, and even cause irreparable damage to the membrane. Therefore, in order to restore good water permeability and desalination performance, chemical cleaning of the membrane is required.
"General3~12It should be cleaned once a month. If it has to be cleaned once a month, it indicates that the pretreatment system should be in place and the operating parameters should be adjusted. If1~3If the equipment needs to be cleaned once a month, it is necessary to improve its operational level. It is rather difficult to determine whether the pretreatment system needs to be improved.
Yuan LaiEDIThe ultra-pure water equipment uses electro-deionization technology.EDIElectrodeionization is a water purification method that combines the dual advantages of electrodialysis and ion exchange. It does not require acid-base chemical regeneration and can continuously and stably prepare high-purity ultrapure water. Under the action of a direct current electric field, ion separation in water is completed. At the same time, water is electrolyzed to generate hydrogen ions and hydroxide ions, achieving automatic regeneration of the resin without the need to stop the machine for manual regeneration. The pre-treatment combined with reverse osmosis can prevent oxidized substances from damaging the resin, ensuring stable effluent quality and widely meeting the high-standard water usage requirements of various industries.
The non-negative pressure water supply equipment can be directly connected to the municipal water supply network, making full use of the residual pressure of the original network for superimposed water supply. Fully enclosed operation does not require the construction of a domestic water tank, eliminating secondary pollution. Intelligent variable frequency voltage stabilization, energy-saving, quiet and easy installation, it is the preferred equipment for secondary water supply in high-rise residential buildings and commercial buildings.
Constant pressure water supply equipment is widely used in central air conditioning, floor heating, industrial closed-loop water circulation, and boiler systems. It integrates automatic pressure stabilization, automatic water replenishment, automatic exhaust, pressure relief and buffering functions. It stabilizes the pressure in the pipeline network, eliminates abnormal sounds caused by air blockage, and prevents damage from negative pressure and water shortage in the pipeline. It is an essential supporting equipment for HVAC and circulating water systems.
Landline:+86 010 59792055
Landline:+86 010 63780188
Mobile:+86 13910114728
Email:bjyuanlai@163.com
Email:Wanda Plaza, Fengke Road, Fengtai District, BeijingBseat6Courtyard No.3Building No.7layer708
Yuanlai Homepage Softened water equipment Reverse osmosis pure water equipment Water supply equipment Engineering case Technical service Enter Yuanlai Site map
Softened water equipment Reverse osmosis pure water equipment Water purification equipment Water supply equipment Automatic dosing equipment High-purity water (ultra-pure water) equipment Wholesale of water treatment accessories
Electric power industry Petrochemical industry The electronic semiconductor industry The photovoltaic new energy industry Pharmaceuticals & Biochemical Engineering School research units Food and beverage industry Enterprises and public institutions
Reverse osmosis membrane Star-counting pump Fleck Valve Runxin Valve Instruments and meters Ultrafiltration membrane Softening resin Resin tank