Common problem analysis and solutions for the dosing system of metering pumps

Released Date: Dec 01,2018 Article Source: Yuanlai Water Treatment
During the long-term operation of the metering pump dosing system, some faults are inevitable. After a malfunction occurs, how to make correct judgments and analyses and confirm the cause of the malfunction is part of the daily work of equipment users and maintenance personnel. Here, the editor has collected and sorted out some common fault phenomena and possible causes related to metering pumps, which can be used for reference and learning by everyone!

During the long-term operation of the metering pump dosing system, some faults are inevitable. After a malfunction occurs, how to make correct judgments and analyses and confirm the cause of the malfunction is part of the daily work of equipment users and maintenance personnel.


       Here, the editor has collected and sorted out some common fault phenomena and possible causes related to metering pumps, which can be used for reference and learning by everyone!


1.Often related to system configurationSee fault

1.1 Insufficient traffic

Cause of malfunction

Solution

The flow rate of the metering pump is relatively large, and the diameter of the inlet pipeline is too small, resulting in insufficient suction of the pump

1.Increase the diameter of the inlet pipeline to ensure that the pump is fully sucked in

2.Increase the inlet pressure to ensure that the pump is fully sucked in

There is a leakage in the inlet pipeline

Inlet pipeline

The inlet pipe of the metering pump is too long, resulting in insufficient suction of the pump

1.Increase the diameter of the inlet pipeline to ensure that the pump is fully sucked in

2.Change the installation position of the pump and shorten the length of the inlet pipeline

3.Add a riser near the inlet of the metering pump to improve the suction conditions

The metering pump is installed for lifting purposes, and there is no foot valve installed at the bottom of the inlet pipe

Add a foot valve at the bottom of the inlet pipe

There is internal leakage in the valve configured at the outlet of the metering pump, resulting in insufficient outlet flow

Repair or replace the valve



1.2 Excessive traffic / (Adjusting the stroke, the flow rate does not change significantly.)

Cause of malfunction

Solution

The outlet pressure of the metering pump is lower than the inlet pressure, resulting in siphoning

Install a back pressure valve in the outlet pipeline of the metering pump to ensure the pressure difference between the outlet and inlet of the metering pump


Common faults related to electrical control

2.1 The pump motor is not running

Cause of malfunction

Solution

Power supply issue

1.Confirm whether the power supply mode is correct.220/380VThe motor is a dual-voltage motor and is powered by three-phase power.

2.Is there a phase loss in the motor power supply? Confirm with a voltmeter.

3.Whether the overload protection is triggered. It needs to be reset or reconfigured.

4.Is there an internal open circuit in the power supply cable? Confirm with a multimeter.

5.Whether there is an open circuit inside the motor. Confirm with a multimeter.

6.Confirm whether the resistances of the three-phase windings of the motor are consistent.


2.2 The pump motor is not running

Recommend products

EDI ultra-pure water system

EDI ultra-pure water system

Yuan LaiEDIThe ultra-pure water equipment uses electro-deionization technology.EDIElectrodeionization is a water purification method that combines the dual advantages of electrodialysis and ion exchange. It does not require acid-base chemical regeneration and can continuously and stably prepare high-purity ultrapure water. Under the action of a direct current electric field, ion separation in water is completed. At the same time, water is electrolyzed to generate hydrogen ions and hydroxide ions, achieving automatic regeneration of the resin without the need to stop the machine for manual regeneration. The pre-treatment combined with reverse osmosis can prevent oxidized substances from damaging the resin, ensuring stable effluent quality and widely meeting the high-standard water usage requirements of various industries.

Non-negative pressure water supply equipment

Non-negative pressure water supply equipment

The non-negative pressure water supply equipment can be directly connected to the municipal water supply network, making full use of the residual pressure of the original network for superimposed water supply. Fully enclosed operation does not require the construction of a domestic water tank, eliminating secondary pollution. Intelligent variable frequency voltage stabilization, energy-saving, quiet and easy installation, it is the preferred equipment for secondary water supply in high-rise residential buildings and commercial buildings.

Constant pressure water supply equipment

Constant pressure water supply equipment

Constant pressure water supply equipment is widely used in central air conditioning, floor heating, industrial closed-loop water circulation, and boiler systems. It integrates automatic pressure stabilization, automatic water replenishment, automatic exhaust, pressure relief and buffering functions. It stabilizes the pressure in the pipeline network, eliminates abnormal sounds caused by air blockage, and prevents damage from negative pressure and water shortage in the pipeline. It is an essential supporting equipment for HVAC and circulating water systems.

Contact us

  • Wanda Plaza, Fengke Road, Fengtai District, BeijingBseat6Courtyard No.3Building No.7layer708
  • bjyuanlai@163.com
  • +86 010 59792055
  • +86 010 59792055

All rights reserved © 2026 Beijing Yuanlai Water Treatment Equipment Co., LTD All rights reserved