8 Precautions for the Installation and Operation of PE Water Tanks
The PE water tanks frequently used in water treatment are made of polyethylene material. They are tough in texture, light and tough, and have excellent corrosion resistance. Clean and beautiful Economical and durable, heat and cold resistant, odorless, meeting drinking water standards, and customizable, it is widely favored by all sectors. Now let's talk about 8 precautions for the installation and operation of PE plastic water tanks and storage tanks. 1. The cement ground foundation for installing the PE water tank should be level and capable of withstanding the corresponding load-bearing force. If it is used in an air steel structure, the gap should not be too large, and iron plates should be laid on top to keep it level and ensure that the bottom surface of the PE storage tank is flat, so as to increase the service life of the PE storage tank. Please remove any sharp objects or stones from the PE storage tank placement area. Due to the fact that the bottom of the PE storage tank inevitably protrudes into the tank during the molding process, a spherical crown is formed
Details >The calculation method and precautions for the desalination rate of reverse osmosis (RO) membranes
Reverse osmosis (RO) membranes are the core components for achieving reverse osmosis. They are artificial semi-permeable membranes with certain characteristics made by simulating biological semi-permeable membranes. The pore size of reverse osmosis (RO) membranes is extremely small, thus they can effectively remove dissolved salts, colloids, microorganisms, organic matter and other substances from water. The system has the advantages of good water quality, low energy consumption, no pollution, simple process and easy operation. The desalination rate is one of the key factors determining the performance of reverse osmosis (RO) membranes. Now let's talk about the calculation method of the desalination rate of reverse osmosis (RO) membranes. The common test conditions for desalination rate are 225psi (15.5bar), a test solution concentration (NaCl) of 2000ppm, and a recovery rate of 15%. Ii. Calculation Method of Desalination Rate Desalination rate =1- (effluent conductivity/Influent conductivity), for example: Influent conductivity 300, first-grade fresh water 10
Details >7 Points to Note when Selecting Metering Pumps
The metering pump, also known as the quantitative pump or proportional pump, is a special positive displacement pump that can meet the requirements of various strict process flows. Its flow rate can be adjusted steplessly within the range of 0-100%, and it is used to transport liquids (especially corrosive liquids). It is a commonly used accessory in water treatment equipment. Now let's talk about 7 points to note when selecting a metering pump. 1. The rated pressure of the metering pump selected for operating pressure should be slightly higher than the actual required pressure, ranging from 10% to 20%. Excessive pressure will waste energy, increase the investment and operating costs of equipment, so do not choose too high pressure. Second, the flow rate of the metering pump selected for operation should also be measured. Required flow rate. The application range of the flow rate of the metering pump is 30% to 100% of the rated flow rate range of the metering pump. At this time, the repeatability accuracy of the metering pump is high. From the perspective of operating costs
Details >Comparison of cation (001*7), anion (201*7) and mixed bed resin regeneration methods
Ion exchange resins are commonly used in water treatment in our production and daily life. To make full use of them and bring us more reasonable and effective convenience, the following compares the regeneration methods of cationic (001*7), anionic (201*7) and mixed bed resins. 1. 001× 7 Cation exchange resin 1. Pretreatment of the resin: Load the resin into the exchanger and backwash it with clean water. The effluent is clear as. First, introduce approximately 4%NaOH, which is twice the volume of the resin. Soak the resin in the latter volume of NaOH solution for 4 to 8 hours, then rinse with clean water until the pH is around 9. Next, introduce about 4%HCl, which is twice the volume of the resin. Soak the resin in the latter volume of hydrochloric acid solution for 4 to 8 hours, then rinse with clean water until the pH is around 5. 2. Regenerate A. Use about twice the volume of resin
Details >The activated carbon filter is a commonly used water treatment device. As a pretreatment for the water treatment desalination system, it can adsorb the residual chlorine that cannot be removed in the previous stage of filtration, effectively ensuring the service life of the subsequent equipment, improving the quality of the effluent, and preventing pollution, especially the free residual oxygen poisoning pollution of the reverse osmosis membrane and ion exchange resin in the subsequent stage. It also adsorbs small-molecule organic substances and other pollutants that leak from the previous stage. It has a relatively obvious adsorption and removal effect on water odors, colloids and pigments, heavy metal ions, etc., and also has the function of reducing COD. The SDI value of the RO feed water can be further reduced. The specific functions of the activated carbon filter include: 1. Removing color and odor; 2. It can adsorb organic matter, colloidal particles and microorganisms in water. 3. It can adsorb oxygen, ammonia and bromine
Details >
Yuan LaiEDIThe ultra-pure water equipment uses electro-deionization technology.EDIElectrodeionization is a water purification method that combines the dual advantages of electrodialysis and ion exchange. It does not require acid-base chemical regeneration and can continuously and stably prepare high-purity ultrapure water. Under the action of a direct current electric field, ion separation in water is completed. At the same time, water is electrolyzed to generate hydrogen ions and hydroxide ions, achieving automatic regeneration of the resin without the need to stop the machine for manual regeneration. The pre-treatment combined with reverse osmosis can prevent oxidized substances from damaging the resin, ensuring stable effluent quality and widely meeting the high-standard water usage requirements of various industries.
The non-negative pressure water supply equipment can be directly connected to the municipal water supply network, making full use of the residual pressure of the original network for superimposed water supply. Fully enclosed operation does not require the construction of a domestic water tank, eliminating secondary pollution. Intelligent variable frequency voltage stabilization, energy-saving, quiet and easy installation, it is the preferred equipment for secondary water supply in high-rise residential buildings and commercial buildings.
Constant pressure water supply equipment is widely used in central air conditioning, floor heating, industrial closed-loop water circulation, and boiler systems. It integrates automatic pressure stabilization, automatic water replenishment, automatic exhaust, pressure relief and buffering functions. It stabilizes the pressure in the pipeline network, eliminates abnormal sounds caused by air blockage, and prevents damage from negative pressure and water shortage in the pipeline. It is an essential supporting equipment for HVAC and circulating water systems.
Landline:+86 010 59792055
Landline:+86 010 63780188
Mobile:+86 13910114728
Email:bjyuanlai@163.com
Email:Wanda Plaza, Fengke Road, Fengtai District, BeijingBseat6Courtyard No.3Building No.7layer708
Yuanlai Homepage Softened water equipment Reverse osmosis pure water equipment Water supply equipment Engineering case Technical service Enter Yuanlai Site map
Softened water equipment Reverse osmosis pure water equipment Water purification equipment Water supply equipment Automatic dosing equipment High-purity water (ultra-pure water) equipment Wholesale of water treatment accessories
Electric power industry Petrochemical industry The electronic semiconductor industry The photovoltaic new energy industry Pharmaceuticals & Biochemical Engineering School research units Food and beverage industry Enterprises and public institutions
Reverse osmosis membrane Star-counting pump Fleck Valve Runxin Valve Instruments and meters Ultrafiltration membrane Softening resin Resin tank