Time type Flow-type fully automatic water softening equipment
Our company adopts multi-way valve control systems from American companies such as Artuzu and Fulaike, and designs and produces fully automatic softening equipment in combination with national conditions. It is widely used in the preparation of industrial and civil softened water, such as boiler water supply, heating, supplementary water for air conditioning systems, and good domestic water supply, etc.
The fully automatic softening system mainly consists of multi-way valves, controllers, resin tanks and salt tanks. The multi-way valve is designed with multiple channels in the same valve body.
Technical parameters of the softener
1Raw water hardness≤6[H+]mmol/L
2That is300 mg/L("CaCO3meter)When the hardness of the raw water is6--12[H+]mmol/Lwhen
3It is recommended to adopt two-stage softening or appropriately reduce the output of the effluent
4When the hardness of the raw water≥12[H+]mmol/LIt is recommended to adopt multi-stage softening or contact our company's engineering and technology department for targeted design.
5Effluent hardness≤0.03[H+]mmol/L("CaCO3"Calculate
6Work pressure:0.20--0.50Mpa
7Working temperature:2--49℃
8Raw water turbidity:<5NTU
9System water consumption:<2%
10Regeneration salt consumption:120-180g/lResin (generally acceptable.160g/l"Resin
11Working power supply:AC220V,50HzSingle-phase three-wire system
12Working power consumption:<10W
13Periodic water production capacity:Q=V×E/(IRaw water-I"Effluent
QPeriodic water production capacitym3ort
VResin volume usagem3
IRaw water: Raw water hardness[H+]mmol/L
IEffluent: The hardness of the effluent is required[H+]mmol/L
EThe working exchange capacity of the resinmmol/L,Generally, it is based on the full exchange capacity of the resin60%--70%Calculation.
As long as you understand and provide the following parameters to our technical department, you can accurately select the softener that meets the requirements of your organization's system equipment.
◇ 1. First, you need to provide the system that requires softened water: process water? Heating? Cooling water replenishment? Steam boiler? The steel smelting industry? Chemical and pharmaceutical industry?
◇ 2. System water usage time: Clearly define the operating time/Hourly water consumption/Average value/Peak flow
Does the user need continuous water supply? If necessary, choose the single-valve dual-tank or dual-control dual-bed series; otherwise, the single-valve single-tank system can be selected.
◇ 3. Total hardness of source water? Is the water source municipal tap water? Groundwater? Surface water source (river,The river,For lake water, you need to provide the hardness of the raw water in the area where it will be used. For a certain model of water softener, if the water hardness is high, the periodic water production volume must be less, which in turn leads to frequent regeneration. It is detrimental to the service life of the resin. To avoid this situation, the volume of the resin should be increased, which means choosing a larger model of water softener.
If you are not familiar with the water quality of the water source you are using, you can entrust it to our company's analysis laboratory. We offer free routine water quality analysis.
◇ 4, The required unit flow rate of soft water (tons)/(hours). This is determined by the nature and requirements of the user's equipment, based on which the standard model of the water softener is selected.
◇ 5The setting of the periodic water production capacity
After the model of the water softener is set, the theoretical cycle water production (in tons) can be determined based on the hardness of the raw water and the exchange working capacity of the resin used.
Selection Guidelines for Softening Equipment
◇ 1Controller: From the United StatesFLECKFleckAUTOTROLArtuzu automatic control valveAQUAMATICYAKE Ike
◇ 2Resin tank: Available for selection: DomesticRFPCans, metal-lined plastic cansPE"Inner lining
Import (StelloRFPtank
◇ 3Equipment operation control form:
L- Flow type: Automatically restores when the prepared water volume reaches the set value, which is suitable
Used for the preparation of soft water in all water supply systems.
S- Time-type: It is a regeneration metering method controlled by time, suitable for water supply in systems with stable water consumption, and has a short restoration and regeneration cycle24Hours.
Yuan LaiEDIThe ultra-pure water equipment uses electro-deionization technology.EDIElectrodeionization is a water purification method that combines the dual advantages of electrodialysis and ion exchange. It does not require acid-base chemical regeneration and can continuously and stably prepare high-purity ultrapure water. Under the action of a direct current electric field, ion separation in water is completed. At the same time, water is electrolyzed to generate hydrogen ions and hydroxide ions, achieving automatic regeneration of the resin without the need to stop the machine for manual regeneration. The pre-treatment combined with reverse osmosis can prevent oxidized substances from damaging the resin, ensuring stable effluent quality and widely meeting the high-standard water usage requirements of various industries.
The non-negative pressure water supply equipment can be directly connected to the municipal water supply network, making full use of the residual pressure of the original network for superimposed water supply. Fully enclosed operation does not require the construction of a domestic water tank, eliminating secondary pollution. Intelligent variable frequency voltage stabilization, energy-saving, quiet and easy installation, it is the preferred equipment for secondary water supply in high-rise residential buildings and commercial buildings.
Constant pressure water supply equipment is widely used in central air conditioning, floor heating, industrial closed-loop water circulation, and boiler systems. It integrates automatic pressure stabilization, automatic water replenishment, automatic exhaust, pressure relief and buffering functions. It stabilizes the pressure in the pipeline network, eliminates abnormal sounds caused by air blockage, and prevents damage from negative pressure and water shortage in the pipeline. It is an essential supporting equipment for HVAC and circulating water systems.
Landline:+86 010 59792055
Landline:+86 010 63780188
Mobile:+86 13910114728
Email:bjyuanlai@163.com
Email:Wanda Plaza, Fengke Road, Fengtai District, BeijingBseat6Courtyard No.3Building No.7layer708
Yuanlai Homepage Softened water equipment Reverse osmosis pure water equipment Water supply equipment Engineering case Technical service Enter Yuanlai Site map
Softened water equipment Reverse osmosis pure water equipment Water purification equipment Water supply equipment Automatic dosing equipment High-purity water (ultra-pure water) equipment Wholesale of water treatment accessories
Electric power industry Petrochemical industry The electronic semiconductor industry The photovoltaic new energy industry Pharmaceuticals & Biochemical Engineering School research units Food and beverage industry Enterprises and public institutions
Reverse osmosis membrane Star-counting pump Fleck Valve Runxin Valve Instruments and meters Ultrafiltration membrane Softening resin Resin tank