The ratio of the working exchange capacity of the softened water resin

Released Date: Aug 31,2015 Article Source: Yuanlai Water Treatment
Resin regeneration plays a crucial role in water treatment. There are several influencing factors, such as the purity and dosage of the regenerant. So we need to determine the purity and dosage of the regenerant. It is generally believed that the regeneration effect of hydrochloric acid is better than that of sulfuric acid, and the regeneration cost of sulfuric acid is lower than that of hydrochloric acid. The higher the purity of the regenerant and the lower the impurity content, the higher the degree of resin regeneration, especially having a greater impact on the Perlite softening resin. The dosage of regenerant is an important factor affecting regeneration. It refers to the amount of regenerant used per unit volume of resin, with units of kg/m ³ (resin) or g/L(resin). Another commonly used indicator is the regenerant specific consumption, which refers to the ratio of the amount of regenerant input to the working exchange capacity of the obtained resin. Another representation is the consumption of regenerant, which is the expected unit of work to be obtained

Resin regeneration plays a crucial role in water treatment. There are several influencing factors, such as the purity of the regenerant and its usageQuantity, etc. So we need to determine the purity and dosage of the regenerant.

Purity of regenerant

It is generally believed that the regeneration effect of hydrochloric acid is superior to that of sulfuric acid, and the regeneration cost of sulfuric acid is lower than that of hydrochloric acid. The purity of the regenerant is high, and it contains impuritiesThe smaller the amount, the higher the regeneration degree of the resin, especially having a greater impact on the Perlite softening resin.

Dosage of regenerant

The dosage of regenerant is an important factor affecting regeneration. Its concept refers to the amount of regenerant used per unit volume of resin, with the unit beingkg/m3(Resin)org/L(Resin). Another commonly used indicator is the specific consumption of regenerant, which refers to the amount of regenerant addedThe ratio to the working exchange capacity of the obtained resin. Another representation is the consumption of regenerant, which is the expected unit of work to be obtainedPure regenerative dose required for exchange capacity, unitg/mol.

Increasing the dosage of the regenerant can enhancePUROLITEThe regeneration degree of the resin, but when the specific consumption of the regenerant increases to a certain extent, the improvement in the regeneration degree is not obvious. The amount of regenerant required is related to the properties of the ion exchange resin. Generally, the amount of regenerant needed for strong-type resins is higher than that for weak-type resins. The amount of regenerant used varies with different regeneration methods, and the amount of regenerant used should be higher than that used in countercurrent regeneration. When the regeneration method of softening resin adopts co-current flow, since the regenerant first comes into contact with the exhausted resin at the top, this part of the resin is well regenerated. When the regenerant flows down again and comes into contact with the resin at the bottom of the exchanger,It seriously affected the regeneration degree of the exchange resin, causing this part of the resin to not be fully regenerated and thus influencing the effluent quality. If the regeneration degree of this part of the resin is to be enhanced, the amount of regenerant used should be increased.

Softened PerliteA600When the resin regeneration method adopts countercurrent, since the resin at the bottom of the exchanger is always in contact with fresh regenerant, a very high degree of regeneration can be achieved. During operation, water comes into contact with this part of the highly regenerated resin, ensuring the quality of the effluent water. When countercurrent regeneration is adopted, the regeneration degree of the resin at the upper part of the water treatment equipment exchanger is poor. Although it first comes into contact with the influent water, due to the low ion content exchanged from the resin in the water, ion exchange can still be carried out, and the exchange capacity of this part of the resin can still be fully utilized.

Therefore, improving the purity and dosage of the Purlite water softening regenerant in this way is an important aspect that we need to control well. Only by grasping these points well can the role of the water softening resin be fully exerted.

Recommend products

EDI ultra-pure water system

EDI ultra-pure water system

Yuan LaiEDIThe ultra-pure water equipment uses electro-deionization technology.EDIElectrodeionization is a water purification method that combines the dual advantages of electrodialysis and ion exchange. It does not require acid-base chemical regeneration and can continuously and stably prepare high-purity ultrapure water. Under the action of a direct current electric field, ion separation in water is completed. At the same time, water is electrolyzed to generate hydrogen ions and hydroxide ions, achieving automatic regeneration of the resin without the need to stop the machine for manual regeneration. The pre-treatment combined with reverse osmosis can prevent oxidized substances from damaging the resin, ensuring stable effluent quality and widely meeting the high-standard water usage requirements of various industries.

Non-negative pressure water supply equipment

Non-negative pressure water supply equipment

The non-negative pressure water supply equipment can be directly connected to the municipal water supply network, making full use of the residual pressure of the original network for superimposed water supply. Fully enclosed operation does not require the construction of a domestic water tank, eliminating secondary pollution. Intelligent variable frequency voltage stabilization, energy-saving, quiet and easy installation, it is the preferred equipment for secondary water supply in high-rise residential buildings and commercial buildings.

Constant pressure water supply equipment

Constant pressure water supply equipment

Constant pressure water supply equipment is widely used in central air conditioning, floor heating, industrial closed-loop water circulation, and boiler systems. It integrates automatic pressure stabilization, automatic water replenishment, automatic exhaust, pressure relief and buffering functions. It stabilizes the pressure in the pipeline network, eliminates abnormal sounds caused by air blockage, and prevents damage from negative pressure and water shortage in the pipeline. It is an essential supporting equipment for HVAC and circulating water systems.

Contact us

  • Wanda Plaza, Fengke Road, Fengtai District, BeijingBseat6Courtyard No.3Building No.7layer708
  • bjyuanlai@163.com
  • +86 010 59792055
  • +86 010 59792055

All rights reserved © 2026 Beijing Yuanlai Water Treatment Equipment Co., LTD All rights reserved