Location: Home » News Updates » Industry Trends » Why do industrial boilers need to use water softening equipment?
font: Big Middle Small

Why do industrial boilers need to use water softening equipment?

Released Date: Jun 03,2019 Article Source: Yuanlai Water Treatment
The power boiler softened water equipment is a complete machine composed of a soft water controller, resin tank, strong acid type sodium ion cation resin and salt tank. It features small volume, simple operation and automatic operation without manual operation. It has been widely used in industrial boilers, cooling circulating water, steelmaking, steel rolling, large transformers, civil hot water boilers and other occasions. Everyone knows that water can be classified as hard or soft. It is often heard that when people talk about water quality, they reflect the hardness or softness of the water. The hardness or softness of water represents the difference in substances it contains, generally referring to the amount of salts dissolved in water, such as magnesium and calcium salts. If the content is high, it is hard water; otherwise, it is soft water. Relatively speaking, hard water is more harmful to people. The hardness of water that can be boiled and that that cannot in hard water is the total hardness of water. When water is too hard, it can cause certain harm to the human body.

The power boiler softened water equipment is a complete machine composed of a soft water controller, resin tank, strong acid type sodium ion cation resin and salt tank. It features small volume, simple operation and automatic operation without manual operation. It has been widely used in industrial boilers, cooling circulating water, steelmaking, steel rolling, large transformers, civil hot water boilers and other occasions.

Everyone knows that water can be classified as hard or soft. It is often heard that when people talk about water quality, they reflect the hardness or softness of the water. The hardness or softness of water represents the difference in substances it contains, generally referring to the amount of salts dissolved in water, such as magnesium and calcium salts. If the content is high, it is hard water; otherwise, it is soft water.

Relatively speaking, hard water is more harmful to people. The hardness of water that can be boiled and that that cannot in hard water is the total hardness of water. When water is too hard, it can cause certain harm to the human body. The state has requirements for the hardness of drinking water. The so-called "water and soil incompatibility" refers to the gastrointestinal discomfort symptoms caused by people who don't often drink hard water drinking hard water. Therefore, the hardness of water needs to be artificially adjusted to ensure better absorption by the human body.

Soften work management

1Establish a soft water operation system

To ensure the economic operation of the boiler, a basic system for soft water operation should be established.

2Regularly flush the boiler and evaluate the softening water effect.

The purpose of regularly flushing the boiler

1Thoroughly clean the accumulated soft mud in the boiler to prevent the formation of regenerative scale.

2Thoroughly clean the loose and fallen old scale during operation to prevent pipeline blockage.

3The soft scale adhering to the surface of the furnace and tube walls prevents it from turning into hard scale.

4Check the growth of scale on each heat transfer surface inside the boiler and measure whether the thickness has increased to determine the softening effect of the water.

5Check the technical condition of each part of the boiler and the boiler equipment, such as valves, pressure gauges, blowdown valves, etc., to ensure the maintenance of valves, pressure gauges, blowdown valves, etc., and to guarantee operation.

The period for flushing the softened water equipment of electric boilers: For production boilers using water treatment inside the boiler, it is advisable to do it once a month; for heating boilers, it should be carried out once during the middle of a heating period;For boilers that use soft water outside the boiler, the flushing cycle can be appropriately extended.

The purpose of analyzing scale is mainly from feed water, boiler water, mud scale and water scaleCaO,MgO,SiO2The ratio of the scale and the physical properties of the scale are studied to study the formation law of the scale, so as to take improvement measures and enhance the effect of water treatment.

In conclusion, the water treatment work inside electric boilers not only requires a formula tailored to the water quality conditions but also strict technical management and supervision to achieve better results.


Recommend products

EDI ultra-pure water system

EDI ultra-pure water system

Yuan LaiEDIThe ultra-pure water equipment uses electro-deionization technology.EDIElectrodeionization is a water purification method that combines the dual advantages of electrodialysis and ion exchange. It does not require acid-base chemical regeneration and can continuously and stably prepare high-purity ultrapure water. Under the action of a direct current electric field, ion separation in water is completed. At the same time, water is electrolyzed to generate hydrogen ions and hydroxide ions, achieving automatic regeneration of the resin without the need to stop the machine for manual regeneration. The pre-treatment combined with reverse osmosis can prevent oxidized substances from damaging the resin, ensuring stable effluent quality and widely meeting the high-standard water usage requirements of various industries.

Non-negative pressure water supply equipment

Non-negative pressure water supply equipment

The non-negative pressure water supply equipment can be directly connected to the municipal water supply network, making full use of the residual pressure of the original network for superimposed water supply. Fully enclosed operation does not require the construction of a domestic water tank, eliminating secondary pollution. Intelligent variable frequency voltage stabilization, energy-saving, quiet and easy installation, it is the preferred equipment for secondary water supply in high-rise residential buildings and commercial buildings.

Constant pressure water supply equipment

Constant pressure water supply equipment

Constant pressure water supply equipment is widely used in central air conditioning, floor heating, industrial closed-loop water circulation, and boiler systems. It integrates automatic pressure stabilization, automatic water replenishment, automatic exhaust, pressure relief and buffering functions. It stabilizes the pressure in the pipeline network, eliminates abnormal sounds caused by air blockage, and prevents damage from negative pressure and water shortage in the pipeline. It is an essential supporting equipment for HVAC and circulating water systems.