Location: Home » News Updates » Q&A » The consequences of improper operation of the reverse osmosis edi device
font: Big Middle Small

The consequences of improper operation of the reverse osmosis edi device

Released Date: Apr 09,2016 Article Source: Yuanlai Water Treatment
The reverse osmosis edi device is an industrial high-purity water equipment that combines reverse osmosis technology and EDI technology. It has excellent working efficiency and water quality. During the application of this equipment, if the operation is improper, the performance of its main component, the reverse osmosis membrane, may be damaged. Therefore, to avoid such problems, the following points should be particularly noted. There are usually two situations where residual gas in the permeation equipment operates under high pressure, forming air hammers that can damage the membrane: A. After the equipment is emptied, when it is restarted, the pressure is rapidly increased without completely discharging the gas. The remaining air should be completely discharged at a pressure of 2 to 4bar before gradually increasing the pressure for operation. B. When the joint between the pretreatment equipment and the high-pressure pump is not well sealed or leaks (especially when the microfilter and the pipeline after it leak), when pretreatment

  Reverse osmosisediThe device is composed of reverse osmosis technology andEDIThe industrial high-purity water equipment, which is formed by the combination of technologies, has excellent working efficiency and water quality. During the application of this equipment, if the operation is improper, the performance of its main component, the reverse osmosis membrane, may be damaged. Therefore, to avoid such problems, the following points should be particularly noted.

  1There is residual gas in the permeation equipment operating under high pressure,The formation of an air hammer will damage the film

  There are often two situations occurring:

  AAfter the equipment is emptied,When re-running,The gas was rapidly pressurized before it was completely discharged. Should be2~4barAfter the remaining air is completely expelled under the pressure,Then gradually increase the voltage for operation.

  BWhen the joint between the pretreatment equipment and the high-pressure pump is not well sealed or leaks water(Especially the leakage of the microfilter and the pipeline behind it)When the pre-treated water supply is insufficient,If the microfilter gets clogged,In poorly sealed areas, some air may be drawn in due to vacuum. The microfilter should be cleaned or replaced,Ensure that the pipeline does not leak. In conclusion,The flowmeter should be gradually pressurized and operated when there are no bubbles in it,If bubbles are found during operation, the pressure should be gradually reduced to check the cause.

  2The method of shutting down the osmotic equipment is incorrect

  AWhen shutting down, the voltage was rapidly reduced without thorough flushing. Because the concentration of inorganic salts on the concentrated water side of the membrane is higher than that of the raw water,It is prone to scaling and contaminating the membrane.BRinse with pre-treated water containing chemical reagents. Water containing chemical reagents may cause membrane fouling during the equipment's shutdown period.

  When the reverse osmosis equipment is about to be shut down,The addition of chemical reagents should be stopped,Gradually reduce the blood pressure3barRinse both sides with pre-treated water10min,Directly concentrated waterTDSWith the original waterTDSStop when it's very close.

  3Microbial contamination is caused by poor maintenance of the penetration equipment

  This is a common problem in the use of composite polyamide membranes,Because polyamide membranes have poor resistance to residual chlorine,Chlorine and other agents were not added correctly during use,In addition, users do not pay enough attention to the prevention of microorganisms,It is prone to cause microbial contamination. At present, many manufacturers produce pure water with excessive microorganisms,It was caused by poor maintenance.

  The main manifestations are:

  When leaving the factory,ROThe equipment was not maintained with liquid;After the equipment was installed, the entire pipeline and pretreatment equipment were not inspected;Intermittent operation without taking maintenance measures;The pretreatment equipment and reverse osmosis equipment were not regularly inspected;The maintenance fluid has expired or its concentration is insufficient.

  Reasonable operation of ultrapure water equipment is an important condition for ensuring its long-term stable operation. Therefore, when applying industrial ultrapure water equipment, users should fully understand the issues that need attention during the operation of the equipment.


Recommend products

EDI ultra-pure water system

EDI ultra-pure water system

Yuan LaiEDIThe ultra-pure water equipment uses electro-deionization technology.EDIElectrodeionization is a water purification method that combines the dual advantages of electrodialysis and ion exchange. It does not require acid-base chemical regeneration and can continuously and stably prepare high-purity ultrapure water. Under the action of a direct current electric field, ion separation in water is completed. At the same time, water is electrolyzed to generate hydrogen ions and hydroxide ions, achieving automatic regeneration of the resin without the need to stop the machine for manual regeneration. The pre-treatment combined with reverse osmosis can prevent oxidized substances from damaging the resin, ensuring stable effluent quality and widely meeting the high-standard water usage requirements of various industries.

Non-negative pressure water supply equipment

Non-negative pressure water supply equipment

The non-negative pressure water supply equipment can be directly connected to the municipal water supply network, making full use of the residual pressure of the original network for superimposed water supply. Fully enclosed operation does not require the construction of a domestic water tank, eliminating secondary pollution. Intelligent variable frequency voltage stabilization, energy-saving, quiet and easy installation, it is the preferred equipment for secondary water supply in high-rise residential buildings and commercial buildings.

Constant pressure water supply equipment

Constant pressure water supply equipment

Constant pressure water supply equipment is widely used in central air conditioning, floor heating, industrial closed-loop water circulation, and boiler systems. It integrates automatic pressure stabilization, automatic water replenishment, automatic exhaust, pressure relief and buffering functions. It stabilizes the pressure in the pipeline network, eliminates abnormal sounds caused by air blockage, and prevents damage from negative pressure and water shortage in the pipeline. It is an essential supporting equipment for HVAC and circulating water systems.

Contact us

  • Wanda Plaza, Fengke Road, Fengtai District, BeijingBseat6Courtyard No.3Building No.7layer708
  • bjyuanlai@163.com
  • +86 010 59792055
  • +86 010 59792055

All rights reserved © 2026 Beijing Yuanlai Water Treatment Equipment Co., LTD All rights reserved