Points to note for the daily operation and maintenance of metering pumps in winter

Released Date: Dec 03,2015 Article Source: Yuanlai Water Treatment
The metering pump is a special positive displacement pump that can meet the requirements of various strict process flows. Its flow rate can be adjusted steplessly within the range of 0-100%, and it is used to transport liquids, especially corrosive liquids. Metering pumps are also known as quantitative pumps or proportional pumps. The metering pump belongs to the reciprocating positive displacement pump and is used for precise metering. Generally, the stability accuracy of the metering pump is required not to exceed ± ± ±. 1%. Generally speaking, there are two types of metering pumps: plunger metering pumps and diaphragm metering pumps. The plunger metering pump has the advantages of high metering accuracy, wide adjustment range and high pressure. However, there is leakage at the packing seal. After the packing is corroded and worn, it will affect the metering accuracy of the pump. The flow rate of this type of metering pump is generally 4 to 4000 liters per hour, and the pressure is usually around 5 liters per hour. Below 105 pascals. The main body of the diaphragm metering pump

20091214164026.jpg


The metering pump is a type of pump that can meet the requirements of various strict process flows, and its flow rate can be within0-100%A special positive displacement pump with stepless adjustment within a range, used for conveying liquids (especially corrosive liquids). Metering pumps are also known as quantitative pumps or proportional pumps. The metering pump belongs to the reciprocating positive displacement pump and is used for precise metering. Generally, the stability accuracy of the metering pump is required not to exceed±1%. Generally speaking, there are two types of metering pumps: plunger metering pumps and diaphragm metering pumps.

Plunger metering pumpIt has the advantages of high measurement accuracy, wide adjustment range and high pressure. However, there is leakage at the packing seal. After the packing is corroded and worn, it will affect the measurement accuracy of the pump. The flow rate of this type of metering pump is generally4~4000l/At that time, the pressure is generally around5×105Below par.
  Diaphragm metering pumpIts main advantage is that there is no leakage, so it is particularly suitable for situations where leakage is not allowed, such as transporting flammable, explosive, toxic and radioactive media. It can also be used to transport liquids containing solid particles, so its development is very fast. The flow rate of this type of metering pump is generally within2500l/Below a certain time, the pressure is acceptable35Megapascals.

For metering pumps, what we should all pay attention to is daily maintenance and regular inspection of the product. The purpose of doing this is to ensure the normal operation and use of the product. Now let's talk about the points to note in the daily operation and maintenance of metering pumps in winter.

I. Basic Operation

1When starting or stopping the pump, strictly follow the operating procedures.

2Always keep the surface of the equipment and the surrounding environment clean and tidy.

Ii. Winter Maintenance

1. The lubricating oil is in its initial operation250It needs to be replaced after an hour. From now on, every2500Change the lubricating oil every hour or every six months.

2. Check the check valve and diaphragm every six months and decide whether to replace them based on the actual usage conditions.

3. Ambient temperature is lower than100℃At that time, the winter lubricating oil should be replaced.

Iii. Regular Inspection

1Regularly check whether the flow rate, pressure, current and rotational speed meet the requirements.

2Regularly check whether all parts of the equipment are operating normally and whether there are any abnormalities or leaks.

3Regularly check the oil quantity in the transmission garment box, analyze the oil quality, and replenish or replace it in a timely manner as required.

 

The above are the points to note for the daily operation and maintenance of metering pumps in winter. If you have any questions regarding the operation and maintenance of metering pumps, please consult Beijing Yuanlai Water Treatment Equipment Co., LTD., which focuses on the water treatment industry15In this year, you can trust us!

2.jpg


Recommend products

EDI ultra-pure water system

EDI ultra-pure water system

Yuan LaiEDIThe ultra-pure water equipment uses electro-deionization technology.EDIElectrodeionization is a water purification method that combines the dual advantages of electrodialysis and ion exchange. It does not require acid-base chemical regeneration and can continuously and stably prepare high-purity ultrapure water. Under the action of a direct current electric field, ion separation in water is completed. At the same time, water is electrolyzed to generate hydrogen ions and hydroxide ions, achieving automatic regeneration of the resin without the need to stop the machine for manual regeneration. The pre-treatment combined with reverse osmosis can prevent oxidized substances from damaging the resin, ensuring stable effluent quality and widely meeting the high-standard water usage requirements of various industries.

Non-negative pressure water supply equipment

Non-negative pressure water supply equipment

The non-negative pressure water supply equipment can be directly connected to the municipal water supply network, making full use of the residual pressure of the original network for superimposed water supply. Fully enclosed operation does not require the construction of a domestic water tank, eliminating secondary pollution. Intelligent variable frequency voltage stabilization, energy-saving, quiet and easy installation, it is the preferred equipment for secondary water supply in high-rise residential buildings and commercial buildings.

Constant pressure water supply equipment

Constant pressure water supply equipment

Constant pressure water supply equipment is widely used in central air conditioning, floor heating, industrial closed-loop water circulation, and boiler systems. It integrates automatic pressure stabilization, automatic water replenishment, automatic exhaust, pressure relief and buffering functions. It stabilizes the pressure in the pipeline network, eliminates abnormal sounds caused by air blockage, and prevents damage from negative pressure and water shortage in the pipeline. It is an essential supporting equipment for HVAC and circulating water systems.

Contact us

  • Wanda Plaza, Fengke Road, Fengtai District, BeijingBseat6Courtyard No.3Building No.7layer708
  • bjyuanlai@163.com
  • +86 010 59792055
  • +86 010 59792055

All rights reserved © 2026 Beijing Yuanlai Water Treatment Equipment Co., LTD All rights reserved