Reverse osmosis equipment is to pass raw water throughFine filters, granular activated carbon filters, compressed activated carbon filters, etc., are then pressurized by a pump, and the pore size is utilized1/10000μmReverse osmosis membraneROThe membrane can turn water with a higher concentration into water with a lower concentration, and at the same time isolate all impurities such as industrial pollutants, heavy metals, and viruses that are mixed in the water in large quantities, thereby meeting the physical and chemical indicators and hygiene standards for drinking water and producing pure water.
Reverse osmosis equipment is often used in the electronics industry, pharmaceutical industry, beverage industry, seawater, brackish water extraction, and domestic water supply, etc. Let's talk about it below12aCommon Problems and Causes of Reverse Osmosis equipment.
I.Low water supply pressure
A The feed water flow rate is inappropriate;
B System leakage;
C The inlet water pressure of the high-pressure pump is insufficient or there is water or air leakage in the pump part;
D The filter element of the precision filter is clogged with dirt;
E The high-pressure pump is faulty.
Ii.High water supply pressure
A The outlet door of the high-pressure pump is improperly adjusted;
B The pipe between the high-pressure pump and the reverse osmosis unit is clogged;
C If the concentrated water regulating door is closed too tightly or blocked, the concentrated water discharge flow will be small;
D The recovery rate is too low.
Iii.Low recovery rate
A The feed water flow rate is too high.;
B The water supply pressure or concentration is low.
FourHigh recovery rate
A The water supply pressure is too high;
B Insufficient feed water flow rate;
V.The pressure drop at both ends of the reverse osmosis equipment is high
A The flow rate of concentrated water is high;
B Membrane element contamination;
SixThe high-pressure pump has stopped running
A The outlet pressure of the pump is too high(Greater than1.7MPa);
B The inlet water pressure of the pump is too low(Less than0.05MPa).
Vii.The water output of the reverse osmosis equipment has decreased
A The feed water temperature is low.;
B Low water supply pressure;
C High concentration of concentrated water causes high osmotic pressure;
D Membrane fouling.
Viii.The water output of the reverse osmosis equipment has increased
A High water supply pressure;
B The water supply temperature is high.
IXThe conductivity of the produced water and the concentrated water of the reverse osmosis equipment both increase simultaneously
A The concentrated water pipeline or the concentrated water regulating valve is clogged with dirt;
B The recovery rate is too high.
X.The reverse osmosis equipment has a high electrical conductivity in the produced water, a high electrical conductivity in the concentrated water, and a high pressure drop in each section
Membrane element contamination limits the flow rate of concentrated water.
ElevenThe electrical conductivity of the water produced by reverse osmosis equipment is high, the pressure drop at both ends of each pressure vessel increases, and the flow rate of the product water is low
Membrane element contamination.
TwelveThe pressure drop at both ends of each pressure vessel is large, the flow rate of the product water is low, and the conductivity of the product water increases somewhat
Contamination and blockage of membrane element channels.
The above is12aCommon problems and causes of reverse osmosis equipment: If you have any questions regarding the selection and operation of reverse osmosis equipment, please consult Beijing Yuanlai Water Treatment Equipment Co., LTD., which focuses on the water treatment industry15In this year, you can trust us!

Yuan LaiEDIThe ultra-pure water equipment uses electro-deionization technology.EDIElectrodeionization is a water purification method that combines the dual advantages of electrodialysis and ion exchange. It does not require acid-base chemical regeneration and can continuously and stably prepare high-purity ultrapure water. Under the action of a direct current electric field, ion separation in water is completed. At the same time, water is electrolyzed to generate hydrogen ions and hydroxide ions, achieving automatic regeneration of the resin without the need to stop the machine for manual regeneration. The pre-treatment combined with reverse osmosis can prevent oxidized substances from damaging the resin, ensuring stable effluent quality and widely meeting the high-standard water usage requirements of various industries.
The non-negative pressure water supply equipment can be directly connected to the municipal water supply network, making full use of the residual pressure of the original network for superimposed water supply. Fully enclosed operation does not require the construction of a domestic water tank, eliminating secondary pollution. Intelligent variable frequency voltage stabilization, energy-saving, quiet and easy installation, it is the preferred equipment for secondary water supply in high-rise residential buildings and commercial buildings.
Constant pressure water supply equipment is widely used in central air conditioning, floor heating, industrial closed-loop water circulation, and boiler systems. It integrates automatic pressure stabilization, automatic water replenishment, automatic exhaust, pressure relief and buffering functions. It stabilizes the pressure in the pipeline network, eliminates abnormal sounds caused by air blockage, and prevents damage from negative pressure and water shortage in the pipeline. It is an essential supporting equipment for HVAC and circulating water systems.
Landline:+86 010 59792055
Landline:+86 010 63780188
Mobile:+86 13910114728
Email:bjyuanlai@163.com
Email:Wanda Plaza, Fengke Road, Fengtai District, BeijingBseat6Courtyard No.3Building No.7layer708
Yuanlai Homepage Softened water equipment Reverse osmosis pure water equipment Water supply equipment Engineering case Technical service Enter Yuanlai Site map
Softened water equipment Reverse osmosis pure water equipment Water purification equipment Water supply equipment Automatic dosing equipment High-purity water (ultra-pure water) equipment Wholesale of water treatment accessories
Electric power industry Petrochemical industry The electronic semiconductor industry The photovoltaic new energy industry Pharmaceuticals & Biochemical Engineering School research units Food and beverage industry Enterprises and public institutions
Reverse osmosis membrane Star-counting pump Fleck Valve Runxin Valve Instruments and meters Ultrafiltration membrane Softening resin Resin tank