In order to accelerate the knowledge acquisition process of its employees and enhance the overall quality of the team, Beijing Yuanlai Water Treatment Equipment Co., Ltd. held a lecture on "American Qingli Scale Inhibitor Knowledge" in December. The lecture was organized by Manager Li Guanghua of American Qingli. "American Qingli Scale Inhibitor" Knowledge lecture. The main participants include the Marketing Department, the project department and the sales department. Although this knowledge lecture was held voluntarily, no one was absent when it began. Manager Li Guanghua explained as follows: Qingli Scale Inhibitor is a scale inhibitor and dispersant, especially suitable for water quality with high content of metal oxides, silicon and scale-forming salts. It has a high scale inhibition efficiency and does not coagle with residual coagulants or silicon compounds rich in aluminum and iron
Details >Installation and commissioning of Fleck 5600 water softener
The installation of the water softener should be carried out by connecting the inlet, outlet and sewage outlet pipes as recommended by the manufacturer, and should comply with relevant pipeline specifications. Manually turn the control valve of the water softener to the working position to allow water to flow into the resin tank. When the water flow stops, open the inlet and outlet until all the air in the pipeline is discharged, and then close the inlet and outlet. Note: You can manually rotate the knob at the front of the control valve to set it to different regeneration positions until the water softener is displayed at the desired position. 2. Manually turn the control valve to the backwash position to allow water to flow out of the drain for 3 or 4 minutes. Example figure: 3. Remove the rear cover plate of the control valve. Example Figure: 4. Ensure that the amount of salt used is set as recommended by the manufacturer. If necessary, set the amount of salt according to the setting manual. Manually turn the control valve to the brine refilling position to fill the void with water
Details >South-to-north Water Diversion water purification equipment
In 2015, Beijing Yuanlai Water Treatment Equipment Co., Ltd. carried out water purification equipment for the South-to-North Water Diversion Project to provide water supply services for citizens. Beijing will build ten water plants and their connection projects, the Yizhuang regulating pool, and a 50-kilometer water distribution network. It will achieve joint dispatching of local water, water transferred from outside, and groundwater, enhancing the capital's water resource carrying capacity and the guarantee capacity of the urban water supply system. In order to alleviate the severe shortage of water resources in the north due to floods in the south and droughts in the north. "South-to-north Water Diversion" After decades of investigation, measurement and research by scientific researchers, the overall layout of the South-to-North Water Diversion Project was determined as follows: water will be diverted from the upper, middle and lower reaches of the Yangtze River respectively to meet the development needs of various regions in Northwest and North China, namely the Western Route Project of the South-to-North Water Diversion Project and the South-to-Nor
Details >Water quality standards for softened water equipment
Beijing Yuanlai Water Treatment Equipment Co., Ltd. provides (water quality standards for softened water equipment) : 1. The resistance value of water is related to the size of its resistance value when determining the electrical conductivity of water. A higher resistance value indicates poorer electrical conductivity, while a lower resistance value suggests better electrical conductivity. According to Ohm's Law, when the water temperature is constant, the resistance value R of water is inversely proportional to the vertical cross-sectional area F of the electrode and directly proportional to the distance L between the electrodes. The magnitude of water's resistivity is related to the amount of salt in the water, the concentration of ions in the water, the charge number of ions, and the speed of ion movement. Therefore, the resistivity of pure water is very high, and that of ultrapure water is even higher. The purer the water, the greater its resistivity. 2. The electrical conductivity of water is due to the presence of various dissolved salts in water, which exist in the form of ions. When a pair of electricity is inserted into water
Details >Common units used in water treatment
1. The length of 1 inch (inche) = 25.4 mm (mm) 1 feet (ft) = 30.480 centimeters (cm) = 0.3048 meters (m) & have spent 2. Area: 1 square foot (ft2)=0.093 square meters (m2)1 square meter (m2)=10.75 square feet (ft2) 3. Volume: 1 cubic foot (ft3)=28.317 liters (L)=0.028317 cubic meters (m ³); 1 Gallon (gal, Gallon)=4.54 liters (L) 4. Weight: 1 Pound (lb, Pound)=0.455 kilograms (Kg); 1 grain =64.8 milligrams (mg); 1 kilograin =0.0648 kilograms. 5. Flow
Details >
Yuan LaiEDIThe ultra-pure water equipment uses electro-deionization technology.EDIElectrodeionization is a water purification method that combines the dual advantages of electrodialysis and ion exchange. It does not require acid-base chemical regeneration and can continuously and stably prepare high-purity ultrapure water. Under the action of a direct current electric field, ion separation in water is completed. At the same time, water is electrolyzed to generate hydrogen ions and hydroxide ions, achieving automatic regeneration of the resin without the need to stop the machine for manual regeneration. The pre-treatment combined with reverse osmosis can prevent oxidized substances from damaging the resin, ensuring stable effluent quality and widely meeting the high-standard water usage requirements of various industries.
The non-negative pressure water supply equipment can be directly connected to the municipal water supply network, making full use of the residual pressure of the original network for superimposed water supply. Fully enclosed operation does not require the construction of a domestic water tank, eliminating secondary pollution. Intelligent variable frequency voltage stabilization, energy-saving, quiet and easy installation, it is the preferred equipment for secondary water supply in high-rise residential buildings and commercial buildings.
Constant pressure water supply equipment is widely used in central air conditioning, floor heating, industrial closed-loop water circulation, and boiler systems. It integrates automatic pressure stabilization, automatic water replenishment, automatic exhaust, pressure relief and buffering functions. It stabilizes the pressure in the pipeline network, eliminates abnormal sounds caused by air blockage, and prevents damage from negative pressure and water shortage in the pipeline. It is an essential supporting equipment for HVAC and circulating water systems.
Landline:+86 010 59792055
Landline:+86 010 63780188
Mobile:+86 13910114728
Email:bjyuanlai@163.com
Email:Wanda Plaza, Fengke Road, Fengtai District, BeijingBseat6Courtyard No.3Building No.7layer708
Yuanlai Homepage Softened water equipment Reverse osmosis pure water equipment Water supply equipment Engineering case Technical service Enter Yuanlai Site map
Softened water equipment Reverse osmosis pure water equipment Water purification equipment Water supply equipment Automatic dosing equipment High-purity water (ultra-pure water) equipment Wholesale of water treatment accessories
Electric power industry Petrochemical industry The electronic semiconductor industry The photovoltaic new energy industry Pharmaceuticals & Biochemical Engineering School research units Food and beverage industry Enterprises and public institutions
Reverse osmosis membrane Star-counting pump Fleck Valve Runxin Valve Instruments and meters Ultrafiltration membrane Softening resin Resin tank