Boiler water softening equipment
The main operation process includes five steps: water production, backwashing, regeneration, slow rinsing and fast rinsing. The working principles of all water softening equipment are basically the same, as any water softening equipment based on sodium ion exchange is developed from these five process flows. However, there may be some differences or additional processes depending on the actual production conditions. This article mainly introduces the maintenance process of boiler softened water equipment. The main methods are as follows:
1To prevent the electrical control equipment from burning out, a sealed cover should be installed on the outside of the electrical control equipment.
2Ensure the stability of current and voltage, avoid moisture or water immersion, etc., and prevent the salt used for regeneration from forming salt scale on the salt valve.

Boiler water softening equipment
3Regularly add granular salt to the salt tank to ensure that the salt solution in the tank is always in a supersaturated state. As granular salt contains some impurities, these impurities will deposit in large quantities at the bottom of the salt tank and clog the salt valve. Therefore, it is necessary to clean the impurities at the bottom of the salt tank regularly. When cleaning, fully open the drain valve at the bottom of the salt tank and rinse it with clean water until no impurities flow out.
4Maintenance out of service. Before the water softening equipment is out of use, it should undergo another resin regeneration treatment. During the summer when it is out of use, the water softening equipment should be flushed at least once a month to prevent the excessive reproduction of microorganisms in the exchange tank, which may cause the resin to mold and form lumps. If mold is found on the resin, it should be dealt with promptly. When the resin is not in use during winter, anti-freezing measures should be taken to prevent the water inside from freezing and cracking. The resin can be stored in a salt water solution, and the concentration of the salt water should be adjusted according to the stability of the climate.
Yuan LaiEDIThe ultra-pure water equipment uses electro-deionization technology.EDIElectrodeionization is a water purification method that combines the dual advantages of electrodialysis and ion exchange. It does not require acid-base chemical regeneration and can continuously and stably prepare high-purity ultrapure water. Under the action of a direct current electric field, ion separation in water is completed. At the same time, water is electrolyzed to generate hydrogen ions and hydroxide ions, achieving automatic regeneration of the resin without the need to stop the machine for manual regeneration. The pre-treatment combined with reverse osmosis can prevent oxidized substances from damaging the resin, ensuring stable effluent quality and widely meeting the high-standard water usage requirements of various industries.
The non-negative pressure water supply equipment can be directly connected to the municipal water supply network, making full use of the residual pressure of the original network for superimposed water supply. Fully enclosed operation does not require the construction of a domestic water tank, eliminating secondary pollution. Intelligent variable frequency voltage stabilization, energy-saving, quiet and easy installation, it is the preferred equipment for secondary water supply in high-rise residential buildings and commercial buildings.
Constant pressure water supply equipment is widely used in central air conditioning, floor heating, industrial closed-loop water circulation, and boiler systems. It integrates automatic pressure stabilization, automatic water replenishment, automatic exhaust, pressure relief and buffering functions. It stabilizes the pressure in the pipeline network, eliminates abnormal sounds caused by air blockage, and prevents damage from negative pressure and water shortage in the pipeline. It is an essential supporting equipment for HVAC and circulating water systems.
Landline:+86 010 59792055
Landline:+86 010 63780188
Mobile:+86 13910114728
Email:bjyuanlai@163.com
Email:Wanda Plaza, Fengke Road, Fengtai District, BeijingBseat6Courtyard No.3Building No.7layer708
Yuanlai Homepage Softened water equipment Reverse osmosis pure water equipment Water supply equipment Engineering case Technical service Enter Yuanlai Site map
Softened water equipment Reverse osmosis pure water equipment Water purification equipment Water supply equipment Automatic dosing equipment High-purity water (ultra-pure water) equipment Wholesale of water treatment accessories
Electric power industry Petrochemical industry The electronic semiconductor industry The photovoltaic new energy industry Pharmaceuticals & Biochemical Engineering School research units Food and beverage industry Enterprises and public institutions
Reverse osmosis membrane Star-counting pump Fleck Valve Runxin Valve Instruments and meters Ultrafiltration membrane Softening resin Resin tank