When reverse osmosis equipment(Or device)When the following symptoms occur, chemical cleaning or physical flushing of the reverse osmosis equipment is required:
Under normal feed water pressure, the water production of reverse osmosis equipment decreases compared to the normal value10~15%.
To maintain a normal water production volume, the feed water pressure is increased after temperature correction10~15%.
The quality of the produced water has declined10~15%The salt penetration rate increases10~15%.
Increase in water supply pressure10~15%.
The pressure difference between each section of the reverse osmosis system has increased significantly
Reverse osmosis membrane fouling can lead to a decrease in water production, a decline in desalination rate, and an increase in the pressure difference between the inlet and the concentrated water. Acid and alkali agents are used for cleaning reverse osmosis membranes(ph2-12Under certain conditions)The temperature of the membrane cleaning solution is high45℃. A lot of pollution, especially slime, accumulates over time and is compressed and thickened, which increases the difficulty of cleaning and greatly prolongs the cleaning time.

Reverse osmosis cleaning equipment
1.Cleaning the medicine tank: Chemical cleaning of the medicine tank is usuallyPEorFRPThe material is durablePHScope1-12.
2.Clean the heating device: The cleaning temperature should be as high as possible, for example20-40℃. No more chemical cleaning10℃The following is carried out because the cleaning efficiency is very low. Because a heating device is also required during cleaning.
3.Cleaning agent: Strong acids and alkalis should be selected for cleaning(Such as hydrochloric acid, phosphoric acid, citric acid, sodium hydroxide, etc)Therefore, the choice of chemistry is very important. Sometimes, improper selection of chemicals can cause membrane contamination or even damage.
4.Cleaning pump: The cleaning is an acid and alkali resistant pump with a flow rate12-15m3/hPressure20-30meter.
5.When cleaning, the corresponding pipes, valves and pressure gauges must be installed. Connect the outlet of the pump to the inlet of the membrane, connect the concentrated water pipe to the medicine tank, and install a ball valve before connecting it to the raw water tank. Then, connect the medicine tank and the pump.
Yuan LaiEDIThe ultra-pure water equipment uses electro-deionization technology.EDIElectrodeionization is a water purification method that combines the dual advantages of electrodialysis and ion exchange. It does not require acid-base chemical regeneration and can continuously and stably prepare high-purity ultrapure water. Under the action of a direct current electric field, ion separation in water is completed. At the same time, water is electrolyzed to generate hydrogen ions and hydroxide ions, achieving automatic regeneration of the resin without the need to stop the machine for manual regeneration. The pre-treatment combined with reverse osmosis can prevent oxidized substances from damaging the resin, ensuring stable effluent quality and widely meeting the high-standard water usage requirements of various industries.
The non-negative pressure water supply equipment can be directly connected to the municipal water supply network, making full use of the residual pressure of the original network for superimposed water supply. Fully enclosed operation does not require the construction of a domestic water tank, eliminating secondary pollution. Intelligent variable frequency voltage stabilization, energy-saving, quiet and easy installation, it is the preferred equipment for secondary water supply in high-rise residential buildings and commercial buildings.
Constant pressure water supply equipment is widely used in central air conditioning, floor heating, industrial closed-loop water circulation, and boiler systems. It integrates automatic pressure stabilization, automatic water replenishment, automatic exhaust, pressure relief and buffering functions. It stabilizes the pressure in the pipeline network, eliminates abnormal sounds caused by air blockage, and prevents damage from negative pressure and water shortage in the pipeline. It is an essential supporting equipment for HVAC and circulating water systems.
Landline:+86 010 59792055
Landline:+86 010 63780188
Mobile:+86 13910114728
Email:bjyuanlai@163.com
Email:Wanda Plaza, Fengke Road, Fengtai District, BeijingBseat6Courtyard No.3Building No.7layer708
Yuanlai Homepage Softened water equipment Reverse osmosis pure water equipment Water supply equipment Engineering case Technical service Enter Yuanlai Site map
Softened water equipment Reverse osmosis pure water equipment Water purification equipment Water supply equipment Automatic dosing equipment High-purity water (ultra-pure water) equipment Wholesale of water treatment accessories
Electric power industry Petrochemical industry The electronic semiconductor industry The photovoltaic new energy industry Pharmaceuticals & Biochemical Engineering School research units Food and beverage industry Enterprises and public institutions
Reverse osmosis membrane Star-counting pump Fleck Valve Runxin Valve Instruments and meters Ultrafiltration membrane Softening resin Resin tank