Common sense for maintaining reverse osmosis (RO) equipment

Released Date: Jun 29,2020 Article Source: Yuanlai Water Treatment
Reverse osmosis technology has been widely applied in scientific research, medicine, beverages, seawater desalination and other fields at present. The reverse osmosis (RO) membrane pores of the reverse osmosis equipment produced by Beijing Yuanlai Water Treatment Equipment Co., Ltd. are at the nanometer level. Under certain pressure, RO reverse osmosis membranes can effectively filter out inorganic salts, heavy metal ions, organic substances, colloids, viruses and other impurities in the source water, thus strictly distinguishing pure water that can pass through from concentrated water that cannot. However, the long-term use of reverse osmosis membranes will cause a lot of adsorption to adhere to the membranes, thereby reducing efficiency. How should we maintain reverse osmosis equipment?

Reverse osmosis technology has been widely applied in scientific research, medicine, beverages, seawater desalination and other fields at present. Reverse osmosis equipment produced by Beijing Yuanlai Water Treatment Equipment Co., LTDROThe pore size of reverse osmosis membranes is at the nanometer level.ROUnder certain pressure, reverse osmosis membranes can effectively filter out inorganic salts, heavy metal ions, organic substances, colloids, viruses and other impurities in the source water, thereby strictly distinguishing pure water that can pass through from concentrated water that cannot. However, the long-term use of reverse osmosis membranes will cause a lot of adsorption to adhere to the membranes, thereby reducing efficiency. How should we maintain reverse osmosis equipment?


ROWhat kind of pretreatment is generally required for the system

  The typical composition of a pretreatment system is as follows: coarse filtration(~80Micron)To remove large particles, oxidants such as sodium hypochlorite are added, followed by precise filtration through a multi-media filter or clarifier. Then, sodium bisulfite is added to reduce the residual chlorine and other oxidants. Finally, a security filter is installed before the high-pressure pump inlet. The function of the security filter, as the name suggests, is to serve as a constant safety measure to prevent accidental damage to the impeller and membrane elements of the high-pressure pump by large particles. Water sources with a higher content of suspended particles usually require a higher degree of pretreatment to meet the specified influent requirements. For water sources with high hardness content, it is recommended to use softening or add acid and scale inhibitors, etc. For water sources with high microbial and organic matter content, activated carbon or anti-pollution membrane elements should also be used.


Reverse osmosis process, ion exchange process

  Under many influent conditions, both ion exchange resins and reverse osmosis are technically feasible. The choice of process should be determined by economic comparison. Generally speaking, the higher the salt content, the more economical reverse osmosis is; the lower the salt content, the more economical ion exchange is. Due to the wide popularity of reverse osmosis technology, reverse osmosis has been adopted+Ion exchange process or multi-stage reverse osmosis or reverse osmosis+The combined process of other deep desalination technologies has become a recognized water treatment solution that is more reasonable in terms of technology and economy.

640.webp.jpg

How often should the reverse osmosis pure water machine system be cleaned

  Under normal circumstances, when the standardized flux decreases10~15%At this time, or the desalination rate of the system decreases10~15%Or the operating pressure and the pressure difference between sections increase10~15%It should be cleaned.ROSystem. The frequency of cleaning is directly related to the degree of system pretreatment. WhenSDI15<3At that time, the cleaning frequency may be once a year4"Second;" whenSDI15in5When left or right, the cleaning frequency may need to be doubled.


How long is the system allowed to be shut down without flushing

  If the system uses a post-delay agent, when the water temperature is20~38℃Between them, approximately4Hours; in20℃When it's below, approximately8Hours; If no scale inhibitor is used in the system, approximately1Oh my god.


Reverse osmosis membrane elements can generally be used for several years

  The service life of a membrane depends on its chemical stability, the physical stability of the components, washability, the source of the feed water, pretreatment, cleaning frequency, and the level of operation and management, etc. The reverse osmosis equipment of Beijing Yuanlai Water Treatment Equipment Co., Ltd. is usually3-5More than one year.

640.webp (1).jpg

Recommend products

EDI ultra-pure water system

EDI ultra-pure water system

Yuan LaiEDIThe ultra-pure water equipment uses electro-deionization technology.EDIElectrodeionization is a water purification method that combines the dual advantages of electrodialysis and ion exchange. It does not require acid-base chemical regeneration and can continuously and stably prepare high-purity ultrapure water. Under the action of a direct current electric field, ion separation in water is completed. At the same time, water is electrolyzed to generate hydrogen ions and hydroxide ions, achieving automatic regeneration of the resin without the need to stop the machine for manual regeneration. The pre-treatment combined with reverse osmosis can prevent oxidized substances from damaging the resin, ensuring stable effluent quality and widely meeting the high-standard water usage requirements of various industries.

Non-negative pressure water supply equipment

Non-negative pressure water supply equipment

The non-negative pressure water supply equipment can be directly connected to the municipal water supply network, making full use of the residual pressure of the original network for superimposed water supply. Fully enclosed operation does not require the construction of a domestic water tank, eliminating secondary pollution. Intelligent variable frequency voltage stabilization, energy-saving, quiet and easy installation, it is the preferred equipment for secondary water supply in high-rise residential buildings and commercial buildings.

Constant pressure water supply equipment

Constant pressure water supply equipment

Constant pressure water supply equipment is widely used in central air conditioning, floor heating, industrial closed-loop water circulation, and boiler systems. It integrates automatic pressure stabilization, automatic water replenishment, automatic exhaust, pressure relief and buffering functions. It stabilizes the pressure in the pipeline network, eliminates abnormal sounds caused by air blockage, and prevents damage from negative pressure and water shortage in the pipeline. It is an essential supporting equipment for HVAC and circulating water systems.

Contact us

  • Wanda Plaza, Fengke Road, Fengtai District, BeijingBseat6Courtyard No.3Building No.7layer708
  • bjyuanlai@163.com
  • +86 010 59792055
  • +86 010 59792055

All rights reserved © 2026 Beijing Yuanlai Water Treatment Equipment Co., LTD All rights reserved