Released Date: Apr 06,2023 Article Source: Yuanlai Water Treatment
The main fault phenomena of reverse osmosis systems fall into three categories: reduced water permeability, increased salt permeability (decreased desalination rate), and increased pressure drop. However, there are many causes for these faults. It is necessary to try to identify the essence of the problem from these fault phenomena as soon as possible, so as to implement maintenance and repair measures as soon as possible. Now, let's take a detailed look together at some faults that occur during the operation of reverse osmosis systems and provide relevant solutions!

Pay attention to water treatment equipment, pay attention to Beijing Yuanlai.

Beijing Yuanlai Water Treatment23We have been dedicated to the water treatment industry for many years and offer a full range of water treatment products. From a complete set of water treatment equipment: water softening equipment, automatic water softeners, large-scale reverse osmosisROEquipmentEDIHigh-purity water systems, filter equipment, ultrafiltration equipment, small-scale water purification equipment, dosing systems, etc...

One-stop purchase of water treatment components, consumables and other items for supporting equipment.

-We provide comprehensive and high-quality one-stop supporting services for water treatment projects in various industries: pre-sale consultation+After-sales service Installation, commissioning and technical training of water treatment systems!


Reverse osmosisROPure water equipment

       There are mainly three types of fault phenomena in reverse osmosis systems:The water permeability decreases while the salt permeability increases(The desalination rate has decreased)And the pressure drop has increased. However, there are many causes of these faults. We should try to find the essence of the problem from these fault phenomena as much as possible, so as to implement maintenance and repair measures as soon as possible.

       Now, let's take a detailed look togetherAnalyze some faults that occur during the operation of reverse osmosis systems and provide relevant solutions!

Wechat picture_20230324164647.jpg


0 1


External factors causing reverse osmosis failure




1Reverse osmosis failure caused by changes in the quality of the influent water

◆ Changes in influent water quality;

◆ The pretreatment system cannot be optimized.

2Reverse osmosis faults caused by pretreatment

◆ The filter material of the multi-media filter is disordered or has an uneven flow.

◆ The buffer water tank is severely infested with bacteria and microorganisms.

◆ The filter material of the activated carbon filter is severely powderized or infested with microorganisms.

3Reverse osmosis failure caused by the security filter

◆ The diameter of the security filter is too small.

◆ The quality of the filter element is poor and the filtration accuracy fails to meet the requirements.

◆ The filter element cannot be pressed tightly and is prone to deformation.

4Reverse osmosis faults caused by the scale inhibitor dosing system

◆ The performance of the scale inhibitor does not match the water quality.

◆ The performance of the scale inhibitor metering pump is unreliable.

◆ Excessive dilution of the scale inhibitor and severe contamination of the medicine tank;

◆ The addition of scale inhibitors causes flow deviation.

5Reverse osmosis faults caused by other dosing systems

◆ Inappropriate flocculants cause membrane element contamination.

◆ Excessive addition of oxidants causes the membrane elements to be oxidized.

◆ Excessive addition of reducing agent causes severe fouling of membrane elements.

6Reverse osmosis faults caused by instruments and meters

◆ The concentrated water flow rate is shown to be too large (actually too small), which causes the reverse osmosis recovery rate to be too high and leads to scaling.

◆ The concentrated water flow rate is shown to be too small (actually quite large), which causes the reverse osmosis recovery rate to be too low and generates an excessive pressure difference.

◆ Fluctuations in flow readings cause system judgment errors.


Reverse osmosis equipment.jpg




0 2


Common faults of reverse osmosis devices



1,When the head of the high-pressure pump was selected at the initial design stage, it was too low. As a result, when the temperature or the quality of the influent water changed, the water production volume failed to meet the design requirements.

2,The oxidation of membrane elements leads to an increase in water flux and a decline in the quality of the produced water.

3,The inversion of the salt water sealing ring leads to an excessively high actual recovery rate, resulting in scaling and a decline in water quality.

4,The damage of the salt water sealing ring causes the actual recovery rate to be too high, resulting in scaling and a decline in water quality.

5,OThe damage of the ring causes a decline in the quality of the produced water.

6,The mixed use of new and old membrane elements and different types of membrane elements leads to a decline in system performance.

7,The overlapping or partial overlapping of the concentrated water thrust ring and the concentrated water outlet of the pressure vessel causes an excessively high recovery rate and leads to scaling.

8,The excessive length of the pressure vessel causes concentrated water to leak to the water production side, resulting in a decline in the quality of the produced water.

Recommend products

EDI ultra-pure water system

EDI ultra-pure water system

Yuan LaiEDIThe ultra-pure water equipment uses electro-deionization technology.EDIElectrodeionization is a water purification method that combines the dual advantages of electrodialysis and ion exchange. It does not require acid-base chemical regeneration and can continuously and stably prepare high-purity ultrapure water. Under the action of a direct current electric field, ion separation in water is completed. At the same time, water is electrolyzed to generate hydrogen ions and hydroxide ions, achieving automatic regeneration of the resin without the need to stop the machine for manual regeneration. The pre-treatment combined with reverse osmosis can prevent oxidized substances from damaging the resin, ensuring stable effluent quality and widely meeting the high-standard water usage requirements of various industries.

Non-negative pressure water supply equipment

Non-negative pressure water supply equipment

The non-negative pressure water supply equipment can be directly connected to the municipal water supply network, making full use of the residual pressure of the original network for superimposed water supply. Fully enclosed operation does not require the construction of a domestic water tank, eliminating secondary pollution. Intelligent variable frequency voltage stabilization, energy-saving, quiet and easy installation, it is the preferred equipment for secondary water supply in high-rise residential buildings and commercial buildings.

Constant pressure water supply equipment

Constant pressure water supply equipment

Constant pressure water supply equipment is widely used in central air conditioning, floor heating, industrial closed-loop water circulation, and boiler systems. It integrates automatic pressure stabilization, automatic water replenishment, automatic exhaust, pressure relief and buffering functions. It stabilizes the pressure in the pipeline network, eliminates abnormal sounds caused by air blockage, and prevents damage from negative pressure and water shortage in the pipeline. It is an essential supporting equipment for HVAC and circulating water systems.

Contact us

  • Wanda Plaza, Fengke Road, Fengtai District, BeijingBseat6Courtyard No.3Building No.7layer708
  • bjyuanlai@163.com
  • +86 010 59792055
  • +86 010 59792055

All rights reserved © 2026 Beijing Yuanlai Water Treatment Equipment Co., LTD All rights reserved