Precautions for ultra-pure water equipment
The configuration components adopted by Beijing Yuanlai Water Treatment Equipment Company meet the water demand of different industries. The ultra-pure water equipment has stable water quality, reliable quality and reasonable price. Precautions for ultra-pure water equipment: 1. PP filter element: The new filter element is white. If it has been used for a long time, the surface will accumulate sediment and turn brown, indicating that the filter element is no longer usable. After rinsing off the surface sediment with water, it can still be used for about one week, but it should not be used for a long time. Its lifespan is generally 3 to 6 months. 2. RO reverse osmosis membrane: If the water consumption is within 10 liters per day, it can be flushed 3 to 5 times. If it exceeds 10 liters, it should be flushed more frequently. If it is not used for a long time (such as more than four weeks), it needs to be taken out and soaked in liquid to prevent the growth of bacteria. However, this process is rather troublesome. It is recommended to turn it on frequently and use a small amount of water
Details >Beijing Yuanlai Water Treatment Equipment Co., Ltd. is a specialized environmental protection water treatment company integrating the design, manufacture, installation, commissioning, after-sales service of complete water treatment system engineering, as well as the research and development, production and sales of water treatment equipment and accessories. Due to business development needs, the company has now decided to recruit a group of long-term, stable and good talents from the society. The specific requirements are as follows: Work experience: More than 1 year. Job nature: Full-time position Monthly salary: Negotiable Number of positions to be filled: Business Assistant: 5 positions Purchasing Assistant: 2 positions Financial Assistant: 1 position Sales Assistant: 10 positions Work Location:
Details >The working principle of non-negative pressure water supply equipment
The working principle diagram of the non-negative pressure water supply equipment: The constant-flow tank-type non-negative pressure water supply equipment is directly connected to the municipal water supply network and supplies water by series superimposed pressure on the basis of the remaining pressure of the municipal water supply network. (1) Variable frequency constant pressure water supply: When the water supply volume of the municipal water network is greater than the water consumption of users, the constant flow tank type non-negative pressure water supply equipment provides variable frequency constant pressure water supply. At this time, a certain amount of pressurized water is stored in the constant flow tank. (2) Negative pressure: When the water consumption of users increases, causing the pressure at the connection between the municipal pipeline network and the steady flow tank to drop, and when the pressure drops below the relative pressure 0, a negative pressure is formed in the steady flow tank, and the intake valve of the vacuum suppressor opens, allowing the atmosphere to enter the steady flow tank. At this point, the steady flow tank is equival
Details >Cleaning steps for reverse osmosis membranes
【 Customer Question 】 How to clean a clogged reverse osmosis membrane? 【 Yuanlai Solution 】 Water Supply and process Water Treatment (Separation, Concentration, Classification and Purification) In various industrial production processes, there is often a need to separate, concentrate, classify and purify certain aqueous solutions. The traditional methods used include processes such as sedimentation, filtration, heating, freezing, distillation, extraction and crystallization. These methods exhibit disadvantages such as long processes, high energy consumption, significant material loss, large equipment, low efficiency, and cumbersome operation. The economic benefits that can be achieved by replacing certain traditional technologies with ultrafiltration membrane technology. The reverse osmosis system needs to be cleaned. It is recommended that you clean the RO system when it shows signs of contamination, before it is shut down for a long time, or during regular maintenance as planned.
Details >The raw water pretreatment system for pure water equipment
Pure water equipment, as the name suggests, is a device that produces clean water. With the sharp increase in population, fresh water resources are gradually facing depletion. In this era of water shortage, pure water equipment becomes particularly important. So, what is the raw water pretreatment system of pure water equipment like? Now let me introduce it to you: 1. Raw water Pretreatment system: 1. Raw water pump The function of the raw water pump is to provide raw water pressure for the pretreatment system. If the raw water pressure is sufficient, this equipment does not need to be used. Generally, the raw water pressure is required to be higher than that of ge. 0.3MPa. 2. Raw water tank The function of the raw water tank is simpler: it is used to store raw water. It is just to prevent the raw water from failing to supply the equipment, so it is used as a medium transfer (usually adding a float switch can make the entire system more automated). 3. Quartz sand filtration
Details >
Yuan LaiEDIThe ultra-pure water equipment uses electro-deionization technology.EDIElectrodeionization is a water purification method that combines the dual advantages of electrodialysis and ion exchange. It does not require acid-base chemical regeneration and can continuously and stably prepare high-purity ultrapure water. Under the action of a direct current electric field, ion separation in water is completed. At the same time, water is electrolyzed to generate hydrogen ions and hydroxide ions, achieving automatic regeneration of the resin without the need to stop the machine for manual regeneration. The pre-treatment combined with reverse osmosis can prevent oxidized substances from damaging the resin, ensuring stable effluent quality and widely meeting the high-standard water usage requirements of various industries.
The non-negative pressure water supply equipment can be directly connected to the municipal water supply network, making full use of the residual pressure of the original network for superimposed water supply. Fully enclosed operation does not require the construction of a domestic water tank, eliminating secondary pollution. Intelligent variable frequency voltage stabilization, energy-saving, quiet and easy installation, it is the preferred equipment for secondary water supply in high-rise residential buildings and commercial buildings.
Constant pressure water supply equipment is widely used in central air conditioning, floor heating, industrial closed-loop water circulation, and boiler systems. It integrates automatic pressure stabilization, automatic water replenishment, automatic exhaust, pressure relief and buffering functions. It stabilizes the pressure in the pipeline network, eliminates abnormal sounds caused by air blockage, and prevents damage from negative pressure and water shortage in the pipeline. It is an essential supporting equipment for HVAC and circulating water systems.
Landline:+86 010 59792055
Landline:+86 010 63780188
Mobile:+86 13910114728
Email:bjyuanlai@163.com
Email:Wanda Plaza, Fengke Road, Fengtai District, BeijingBseat6Courtyard No.3Building No.7layer708
Yuanlai Homepage Softened water equipment Reverse osmosis pure water equipment Water supply equipment Engineering case Technical service Enter Yuanlai Site map
Softened water equipment Reverse osmosis pure water equipment Water purification equipment Water supply equipment Automatic dosing equipment High-purity water (ultra-pure water) equipment Wholesale of water treatment accessories
Electric power industry Petrochemical industry The electronic semiconductor industry The photovoltaic new energy industry Pharmaceuticals & Biochemical Engineering School research units Food and beverage industry Enterprises and public institutions
Reverse osmosis membrane Star-counting pump Fleck Valve Runxin Valve Instruments and meters Ultrafiltration membrane Softening resin Resin tank